4.
Check the waveforms output from both OUTPUTs A and B on the
oscilloscope.
Check that the output waveforms are the same as those shown in the
figure and that they are not distorted.
fig.test-lch_50
OUTPUT A : 50 mV/DIV, OUTPUT B : 500 mV/
DIV, 1mS/DIV
5.
Measure the output levels of both OUTPUTs A and B with a noise meter
(JIS-A).
Check that the output levels are the same as those shown in Test Item 7
above.
6.
Remove the DC plug quickly from the adapter jack, and check battery
operation.
Remove the plug quickly, or the machine will be reset. If the machine is reset
every time you remove the plug, the adapter jack contact or some other part
may be defective.
7.
Check that the same waveforms are output and that CHECK LED (red)
is lit.
If the battery is exhauted, LED will light up gloomily.
8.
Check again that the output waveforms are not distorted.
9.
Remove the plug from BASS IN, and check that the CHECK LED goes
out with no waveforms shown (power off).
9. Noise Check
1.
Connect a DC plug to the adapter jack, and a 47 k? short-plug to GUITAR
IN.
2.
Set all the volume controls at to their maximum positions.
3.
Check that CHECK LED (red) is lit.
4.
Measure the residual noise of both OUTPUTs A and B with a noise meter
(JIS-A).
Check that the noise is -92 dBm or lower.
5.
Press the pedal to turn off the CHECK LED (to form a bypass).
6.
Measure the residual noise of both OUTPUTs A and B with a noise meter
(JIS-A).
Check that the noise is -100 dBm or lower.
7.
Connect a monitor speaker to OUTPUT.
8.
Drop the machine twice from a height of 10 cm to apply it shock.
Check that no abnormal noise occurs.
9.
Turn the pedal on and off and turn each volume control, then check that
no abnormal noise occurs.
How to Exit Test Mode
1.
Press the pedal to exit Test mode.
During volume checks 2 through 5, however, you exit volume check if
you press the pedal.
Press the pedal again to exit Test mode.
If an error is found during the DSP or CPU check mentioned in Test Item 1
above, you cannot exit Test mode by pressing the pedal. Remove the DC plug
from the adapter jack, and turn off the power of the machine.
The noise check mentioned in 9. Noise check above is not done in
Test mode, it is done in Normal mode.
How to Test a Specific Item Only
1.
Enter Test mode.
2.
Release pedal. The system checks the DSP and CPU automatically as
mentioned in 1. Check of DSP and CPU above. The CHECK LED
(green) light up if no problem is found.
3.
Choose the next test item you want with MODE volume.
MOMENTARY: 2. - 5. Volume check
GATE/PAN: 6. CODEC(DAC)check
STANDARD: 7. CODEC(ADC)L ch check
ULTRA: 8. CODEC(ADC)R ch check
You can only do a volume check in the following order: RES -> MANUAL ->
DEPTH -> RATE.
If you do the noise check mentioned in 9. Noise check above, dont enter Test
mode, but do it in Normal mode after turning on the power of the machine.